EasyManua.ls Logo

Vivotek IP7330 - Query Status of the Digital Input

Vivotek IP7330
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
User's Manual - 105
localityname string[128] 6/6 the locality name in certificate information
organizationna
me
string[64] 6/6 organization naem in certificate information
unit string[32] 6/6 organizational unit name in certificate information
commonname string[64] 6/6 common name in certificate information
validdays 0 ~ 9999 6/6 certificatation valid period
Query status of the digital input
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/getdi.cgi?[di0]
If no parameter is specified, all the status of digital input will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <length>\r\n
\r\n
[di0=<state>]\r\n
where <state> can be 0 or 1.
Example: Query the status of digital input 1
Request:
http://myserver/cgi-bin/dido/getdi.cgi?di0
Response:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: 7\r\n
\r\n
di0=1\r\n

Table of Contents

Other manuals for Vivotek IP7330

Related product manuals