VIVOTEK
User's Manual - 161
test_ac
<boolean>
0
0/7
Indicate whether to support
test ac key.
version_onvifdaemon
<string>
1.6.0.8
0/7
Indicate ONVIF daemon
version
image_wdrc
<Boolean>
1
0/7
Indicate whether to support
WDR enhanced.
image_ iristype
<string>
piris
0/7
Indicate iris type.
image_ focusassist
<Boolean>
1
0/7
Indicate whether to support
focus assist.
7.28 Customized event script
Group: event_customtaskfile_i<0~2>
PARAMETER
VALUE
Default
SECURITY
(get/set)
DESCRIPTION
name
string[40]
<blank>
6/7
Custom script identification of this
entry.
date
string[20]
<blank>
6/7
Date of custom script.
String length should between 4 to 20
time
string[20]
<blank>
6/7
Time of custom script.
String length should between 4 to 20
7.29 Event setting
Group: event_i<0~2>
PARAMETER
VALUE
Default
SECURITY
(get/set)
DESCRIPTION
name
string[40]
<blank>
6/6
Identification of this entry.
enable
0, 1
0
6/6
Enable or disable this event.
priority
0, 1, 2
1
6/6
Indicate the priority of this event:
0 = low priority
1 = normal priority
2 = high priority
delay
1~999
20
6/6
Delay in seconds before detecting the
next event.
trigger boot,
di,
motion,
seq,
recnotify,
tampering,
vi
boot 6/6 Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
triggerstatus String[40] trigger 6/6 The status for event trigger
di 0~7 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
mdwin 0~7 0 6/6 Indicate the source window id of
motion detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0 0~7 0 6/6 Similar to mdwin. The parameter
takes effect when profile 1 of motion
detection is enabled.
vi 0~7 0 6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input.
The LSB indicates VI 0.
inter 1~999 1 6/6 Interval of snapshots in minutes.