forwarding service.
upnpnatstatus 0~3 0 6/7 The status of UPnP port forwarding,
used internally.
0 = OK, 1 = FAIL, 2 = no IGD
router, 3 = no need for port
forwarding
7.22 System log
Group: syslog
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
enableremotelog <boolean> 0 6/6 Enable remote log.
serverip <IP address> <blank> 6/6 Log server IP address.
serverport 514,
1025~65535
514 6/6 Server port used for log.
level 0~7 6 6/6 Levels used to distinguish the
importance of the
information:
0: LOG_EMERG
1: LOG_ALERT
2: LOG_CRIT
3: LOG_ERR
4: LOG_WARNING
5: LOG_NOTICE
6: LOG_INFO
7: LOG_DEBUG
setparamlevel 0~2 0 6/6 Show log of parameter
setting.
0: disable
1: Show log of parameter
setting set from external.
2. Show log of parameter
setting set from external and
internal.

Table of Contents