EasyManua.ls Logo

Vivreau ViTap-2 - Troubleshooting; No Sparkling Water Resolution; Service Light ON Diagnosis; Water Leak Detection and Repair

Vivreau ViTap-2
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 31
Water Leak
Confirm the leak is
coming from the
Vivreau System.
Repair leak.
Problem resolved
No Sparkling Water
Sparkling
Water Button
Illuminated?
Yes
Confirm CO
2
Cylinder Valve is
Open and Cylinder
is full. Confirm
pressure readings
on CO
2 Regulator.
No
Carbonator must
be reset to get the
Sparkling Water to
work again.
Unplug the
Chiller/Carbonator
and plug back in to
power the system
OFF and back ON
again.
Problem resolved
Problem resolved
Service Light is ON
Does
Still Water
dispense from Still
Dispenser?
Yes
Yes
Is Water
Supply Valve to
System Open and
working?
Check Water Block
and reset if needed.
Investigate other
Water Supply
issues.
No No
Is Still Water
slower than
normal?
Is water
restored?
Yes
No
No
Problem resolved
Carbonator must
be reset to get the
Sparkling Water to
work again.
Unplug the
Chiller/Carbonator
and plug back in to
power the system
OFF and back ON
again.
Change Filter
Yes
Problem resolved

Related product manuals