Vivreau ViTap-2 - Troubleshooting; Dispensing Water Warm Diagnosis; Flat Sparkling Water Fixes

Vivreau ViTap-2
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32 33
Water Is Dispensing Warm
Is Unit
plugged into a
working outlet? (Blue
Power Light
ON.)
Is Compressor
running?
Is Compressor
running?
Is water
being chilled?
No
No
No
No
No
Jump out
Terminals on
Thermostat
Replace
Thermostat
Yes
Once Unit is
powered On, it
may take up to 45
Minutes for the
water to dispense
cold and 4-6 Hours
to maintain a cold
Dispensing
Temperature.
Is the
Condenser Grille
clogged or
obstructed?
No
Yes
Clean the
Condenser Grille
with a Soft Brush
or Cloth and
remove any
obstructions to the
airflow.
Problem resolved
Problem resolved
Once Unit is
powered On, it
may take up to 45
Minutes for the
water to dispense
cold and 4-6 Hours
to maintain a cold
Dispensing
Temperature.
Problem resolved
Yes
Yes
Yes
Yes
Confirm the Water
Supply Feeding
the Unit is a Cold
Water Supply.
Yes
Is water
being
chilled?
Yes
Replace
Compressor
Problem resolved
Replace
Compressor
Problem resolved
No
Sparkling Water is Flat
Is CO2
Cylinder empty?
(CO
2 LED Illuminated)
or below 70 PSI on
Gauge.
Yes
No
No
No
Problem resolved
Flush the Sparkling Water:
1. Switch the Cleaning Mode
Switch Off.
2. Touch and Hold the
Sparkling Button until only
Gas is dispensed.
3. Release the Button and
turn the Cleaning Mode
Switch back on.
4. Let the Unit cycle for 30
seconds and check the
Sparkling Water again.
Replace CO2
Cylinder and/or
make sure CO
2
Cylinder Valve and
Secondary Shutoff
Valve (if equipped)
are open.
Yes
Is the
Sparkling
Water OK?
Yes
Problem resolved
Yes
Is the
Sparkling
Water OK?
Yes