Vivreau ViTap-2 - Troubleshooting; Unit Loud Noise Diagnosis; CO2 LED ON Troubleshooting; CO2 Leak Detection and Repair

Vivreau ViTap-2
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34 35
Yes
No
No
Replace CO
2
Cylinder.
Is the CO2 Cylinder
empty?
CO2 LED is ON.
Yes
Is CO
2
Cylinder Valve or
Secondary Shutoff
Valve closed?
Yes
No
Is the noise
constant and never
stops?
Yes
No
No
Is the
noise after or
during dispensing
Sparkling Water
only?
Yes
Is the
noise during or
after dispensing either
Still or Sparkling
Water?
Open CO
2 Cylinder
and/or Secondary
Shutoff Valve.
Problem resolved
Check CO2 Pressure
Switch and change
if needed.
Problem resolved
Problem resolved
Check for faulty
Agitator.
Problem resolved
Check Refrigeration
System.
Problem resolved
Problem resolved
Confirm Water
Supply Valve is fully
open before
checking for a
clogged Filter.
Problem resolved
Unit makes Loud Noise.
Is the Gasket
between the
Regulator and Tank
in place?
Connect a new CO
2
Cylinder. Monitor
CO
2 level over the
next 24-48 hours
Yes
No
Did new CO2
Cylinder hold
pressure?
Yes
No
Find and correct
CO
2 leak.
Replace Gasket.
Problem resolved Problem resolved
CO2 Leak