EasyManua.ls Logo

VOLTCRAFT HPS-11530 - F) Memory Slot Operation Preset and Set

VOLTCRAFT HPS-11530
106 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
Connect the plus pole (+) of the consumer with the red socket “+” and the minus pole (-) of the consumer with the
blue socket “-” of the respective output (front = “AUX. OUTPUT”, rear = “MAIN OUTPUT”).
Now you can switch on the connected consumer.
The current consumption of the connected consumer is displayed in Ampere (A) in the display (3).
f) Memory Slot Operation “Preset” and “Set”
7KUHH¿[HGYROWDJHVLQFOXGLQJFXUUHQWVHWWLQJVFDQEHVWRUHGLQWKHGHYLFHZLWKWKH³6HW´IXQFWLRQDQGGLUHFWO\VHOHF-
ted through the “Preset” function.
Ex works, all three memory slots (P1, P2, P3) are preset.
They are assigned as follows:
Memory
Type
P1 P2 P3
Voltage Current Voltage Current Voltage Current
HPS-11530
5 V Maximum 13,8 V Maximum
15 V
Maximum
HPS-11560 15 V
HPS-13015 25 V
HPS-13030 25 V
HPS-16015 55 V
Make sure that no consumers are connected.
Activate the “Preset” function through the “MODE” (13) slider on the rear. Put the
switch in the “Preset” position. The front LED display “REAR CONTROL” (6) lights
up. The front rotary controls are now inactive.

Table of Contents

Related product manuals