EasyManua.ls Logo

VOLTCRAFT VC-450 E - E) Inserting and Changing the Battery

VOLTCRAFT VC-450 E
136 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
Proceed as follows for fuse replacement:
- Disconnect the connected measuring lines from the measuring circuit and the meter. Switch off the DMM.
- Openthecasingasdescribedinchapter“OpeningMeter”.
- Replace the defective fuse with a new fuse of the same type and rated current. The fuses have the following values:
Fuse F1 F2
Characteristic Quick-acting Quick-acting
Value FF600mA H 1000 V F11A H 1000V
Dimension 6 x 32 mm 10 x 38 mm
Type Ceramics Ceramics
Item no. 442335 126357
- Close the casing again carefully.
Using mended fuses or bridging the fuse holder is not permitted for safety reasons. It may cause
resorarcexplosions.Neveroperatethemeterwhenitisopen.
e) Inserting and changing the battery
Operation of the meter requires a 9 V block battery (e.g. 1604A). You need to insert a new, charged battery before
initial operation or when the battery change symbol appears on the display.
The battery status is displayed via a dynamic icon. It changes appearance depending on battery status. When the
emptysymbolashes,anewbatterymustbeinsertedtoavoidmeasuringerrors.
The following symbols can be displayed:
Battery full Battery nearly empty Battery empty Battery empty, meter switches off
Proceed as follows to insert or change the batteries:
- Disconnect the meter and the connected measuring lines from all measuring circuits. Remove all measuring lines
from your meter. Switch off the DMM.
- Openthecasingasdescribedinchapter“OpeningMeter”.
- Replacetheatbatterywithanewoneofthesametype.Placeanewbatteryinthebatterycompartment,observing
the correct polarity.
- Close the casing again carefully.

Table of Contents

Related product manuals