Emergency Trimming
If a situation occurs that needs the drive to be trimmed
over the trim limit, the drive can be emergency trim-
med.
IMPORTANT!
When emergency trimming is performed, the auto-
matic stop will not work. The drive can be trimmed
outside the trim ranges, this can damage the boat and
drive.
1 Press the trim button on the control or power trim
panel in the direction the drive needs to be trim-
med. Release the button when the trim limit is
reached.
2 Press the button again and hold it depressed for
more than 5 seconds. The drive starts trimming.
Start after crash-stop
If the engine crash-stops, the following routine must be
performed before the engine can be started again.
1 Move control lever(s) to neutral.
2 Acknowledge any alarms and turn the ignition off.
3 Wait until the system is completely shut down and
all lamps are out.
4 Turn the ignitionon but do not start the engine.
5 Acknowledge any alarms. Start the engine.
In Case of Emergency
47705992 05-2015 © AB VOLVO PENTA 73