112
Fault code register
3.1.2 Y
Explanation: Faulty control lever detection.
Reaction: It is not possible to calibrate the control lever.
Action:
Check that the control lever is connected.
Check that the lever combination is approved by Volvo Penta.
Please contact a Volvo Penta workshop if the fault remains.
3.1.3 Y
Explanation: Too short lever movement between calibration points.
Reaction: It is not possible to calibrate the control lever.
Action:
Check that there is enough room, so that the control lever can reach the end points.
Check the mechanical connection to the potentiometer.
Switch the ignition off, and repeat the calibration procedure.
Check that the control levers are approved by Volvo Penta.
Please contact a Volvo Penta workshop if the fault remains.
3.1.4 Y
Explanation: Incorrect lever calibration procedure.
Reaction: It is not possible to calibrate the control levers.
Action:
Switch the ignition off, and repeat the calibration procedure.
Check that the control levers are approved by Volvo Penta.
Please contact a Volvo Penta workshop if the fault remains.
3.1.6 Y
Explanation: Control lever is not calibrated.
Reaction: It is not possible to activate a control panel.
Action:
Switch the ignition off, and repeat the calibration procedure.
Check that the control levers are approved by Volvo Penta and correctly installed.
Please contact a Volvo Penta workshop if the fault remains.
Check that the control levers are approved by Volvo Penta.
Please contact a Volvo Penta workshop.