Filling with auto shut-off controller (optional
equipment)
Fuel filler pump is installed in the front cover on the
machine’s right side. Use it when filling the fuel in a
tank.
NOTE!
This pump is provided with an electronic overfilling
protection.
1 Open fuel filler cap (A) on the fuel tank.
2 Open the front cover on the machine’s right side.
3 Remove the strainer cover (F) which is installed
to protect the strainer from dust at the end of
hose (B).
4 Put the pump hose with strainer into the fuel
barrel.
5 Press the green start button (C). The pump will
run as long as the tank is not full.
- At any time during the refuelling or when the
drum has been emptied, the pump may be
stopped by pressing the red button (D).
- The pump will automatically stop when the fuel
level sensor is actuated. The pump cannot be
restarted until the fuel from the tank is used.
6 Fold the hose and reinstall the strainer cover.
7 Close the front cover.
8 Close the fuel filler cap on the fuel tank.
NOTICE
Never allow the fuel filling pump to run dry. The
pump may be damaged.
V1155537
A
C
F
B
D
E
A Fuel filler cap
B Fuel filler pump hose
C Start button (green)
D Stop button (red)
E Manual control button
F Strainer cover
Maintenance
Maintenance service, when required
277