Ceramic Master E10 en v2 17
Reloading of the control program (flash)
Form the PC start the program Teraterm Pro.
Go to the menu Setup/Serial Port and perform
following settings:
Com x - Serial port number
Baud Rate - 9600
Data - 8 bit
Parity - none
Stop - 1 bit
Flow Control - none
Transmit Delay - 0ns 1000ms
When the furnace is switched off push and hold the
ENTER button and switch on the furnace.
In the window of Teraterm Pro a message will appear:
VOP Co.
Press Space 1 – Here the program will count
down 10 sec.
If within 10 seconds the SPACE bar (of the PC ) is not
pressed, the furnace will exit from the procedure.
However, if the SPACE bar is pressed within 10 sec. then
the internal program of the furnace will be deleted and
the furnace will wait to load the new program, which is
in HEX format file.
This is done in the following way:
In the program Teraterm Pro go to the menu File/Send
File menu and perform following settings:
Options - select binary
Select the file containing the new program and press
the Open button.
After finishing the data transfer the furnace will start
automatically with the new control program.