11 Troubleshooting
30
100_0201_ts_0003.fm
11.2 Fault table - rechargeable battery
Pictogram LED over
Pictogram
Possible causes Remedial measure
- Fault LED
illuminates.
- Voltage too high. - Disconnect the rechargeable
battery from the machine or
battery charger.
- Fault LED
illuminates
constantly.
- Contacting error.
- Hardware error.
- Clean contacts, dry
if necessary.
- Put machine back into
operation and acknowledge
error by using a touch button.
*
Temperature
LED illuminates.
Temperature error
(over / under tempera-
ture).
- Only operate machine in
the permissible temperature
range.
- Allow the equipment to cool
down if necessary.
- Put machine back into
operation and acknowledge
error by using a touch button.
Maintenance
LED illuminates.
The rechargeable bat-
tery was disabled due to
a fault.
*
*Contact a
Wacker Neuson contact partner.