Maintenance
T00989GB.fm 23
7. Maintenance
7.1 Maintenance schedule
Check all external screw connections for tight fit appox. 8 hours alfter first operation.
Component Maintenance work Maintenance interval
Drive engine First oil change and filter.
approx. 8 hours after
initial start-up
Valve clearance
Cold engine: Check valve clearance, and adjust if
necessary.
Inlet valve 0,1 mm - outlet valve 0,2 mm.
Air filter
Check dry type air filter - clean or replace filter
cartridge if necessary (pay attention to the
maintenance indication). daily
Drive engine Check oil level, if nec. top up oil.
Centre pole height
setting, transport lock
Regrease. weekly
V-belt Check V-belt, if. nec. replace.
monthly
Protective frame
Check attachment screws for tight fit.
Central lifting point
Tow-bar head Check oil level, top up if necessary.
Drive engine
Oil change, change oil filter.
Keep cooling fins free of dirt, clean dry.
Retighten all accessible screw connections.
every 250 hExciter Oil change.
Valve clearance
Cold engine: Check valve clearance, and adjust
if necessary.
Inlet valve 0,1 mm - outlet valve 0,2 mm.
Fuel filter Change filter. every 500 h