8 Use and operation
40
100_0202_op_0009.fm
8.3.2 Cold starting the machine (manual start)
Note: The engine should rotate freely at temperatures below -5 °C.
1. Bring decompression lever to neutral position.
2. Crank the engine with the crank handle anticlockwise until it can rotate no-
ticeably more freely (10 - 20 crank turns).
3. Press the hand lever of the mechanical oil pressure monitoring for 15 sec-
onds.
Note: In the area of the cover of the metering device, remove dirt and take off
the lid.
4. In the metering device add engine oil up to the upper edge.
5. Replace cover and press it in firmly.
Note: Two fillings in succession are necessary.
6. Pull up decompression lever to the hilt.
7. Then start the engine immediately, see chapter Starting the machine (manual
start).
Pos. Designation Pos. Designation
1 Decompression lever 3 Metering device
2 Hand lever oil pressure monitor-
ing

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson DPU 5545 and is the answer not in the manual?

Wacker Neuson DPU 5545 Specifications

General IconGeneral
Engine TypeDiesel
Engine ManufacturerHatz
Frequency69 Hz
Base Plate Length554 mm
Travel Speed24 m/min
Fuel Tank Capacity5.5 L