9 Maintenance
46
100_0202_mt_0008.fm
9.1 Maintenance table
WARNING
Risk of injury due to non-existent or non-functioning safety devices.
Only operate the machine if the safety devices are properly installed and
working.
Do not modify or remove safety devices.
Maintenance work daily h /Y weekly monthly
Clean machine
Inspection for completeness
Inspection for damage
Check engine oil level*
Change engine oil* 25 h /
250 h
Change engine oil filter* 25 h /
250 h
Clean, adjust, repair, change fuel injectors* 1500 h
Clean, adjust, repair, change injection valve* 3000 h
Change fuel filter* 500 h
Check water trap*
Check intake area of the combustion air*
Check air filter maintenance indicator*
Clean air filter cartridge* 500 h
Check tapped clearance** 25 h /
250 h
Check exciter oil level
Change exciter oil 250 h /
1/2 y
Check hydraulic oil level**
Check hydraulic hose lines** 125 h
Check - change V-belt
Check rubber buffer** 125 h

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson DPU 5545 and is the answer not in the manual?

Wacker Neuson DPU 5545 Specifications

General IconGeneral
Engine TypeDiesel
Engine ManufacturerHatz
Frequency69 Hz
Base Plate Length554 mm
Travel Speed24 m/min
Fuel Tank Capacity5.5 L

Related product manuals