10 Maintenance
100_0202_mt_0008.fm 39
4. Unscrew the screw plug from the filler boring and allow the waste oil to drain completely.
5. Tip the machine to the other side and support it.
6. Fill new oil (see chapterTechnical Data for the exciter oil type and volume) in the filler boring. Use an
appropriate and clean filling container.
7. Place the machine level on the ground.
8. Screw the screw plug with seal ring into the filler boring. The torque setting is 100 Nm.
Check battery backup
During maintenance or when working on the battery, check battery backup and replace if necessary.
NOTICE
Collect escaping or overflowing oil and dispose of with the waste oil in an environmentally
friendly manner in accordance with the existing rules and regulations of the legislative
body.
NOTICE
Only fill with the prescribed volume of oil.
NOTICE
Risk of battery damage!
Defective battery backups cause excessive load on the battery, which can lead to failure.