14 Technical data
45
Example
You utilize an EH 25/230
and want to use an extension cable with a length of
30 m.
The machine has an input voltage of 230 V.
According to the table, the extension cable must feature a cross-section area of
2,5 mm
2
.
Machines Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]
EH 65/120 120 1~ 16
<
95 14
<
149 12
<
235 10
Machines Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]
EH 75/240 240 1~ <
21 1,5
<
35 2,5
<
56 4
<
83 6
Machines Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]
EH 75/240 240 1~ – 16
<
96 14
<
152 12
<
240 10