EasyManuals Logo

Wacker Neuson G 25 User Manual

Wacker Neuson G 25
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
wc_tx003570gb_FM10.fm
44
Mobile Generator
Lifting and Transporting
Continued from the previous page.
5. If the brakes did not function, check the voltage of the breakaway battery.
To do so:
a.Remove the cover of the battery box.
b.Remove the wires connected to the breakaway battery (d).
c. Measure the voltage. If 12–14 VDC is not measured, replace or recharge the
breakaway battery.
6. If 12–14 VDC was measured but the brakes did not function, there is a wiring or
mechanical fault with the brakes. Repair any faults before towing.
7. If the brakes function properly:
a.Reconnect the wires to the breakaway battery.
b.Re-install the cover to the battery box.
c. Re-install the breakaway pin (b) into the brake switch.
d.Connect the trailer wiring plug to the tow vehicle.
Result
The procedure to test the breakaway system is now complete.
wc_gr008515
d
VDC
1000
200
20
2
200m
F
V
A
V- COM

Table of Contents