EasyManuals Logo

Wacker Neuson GH 3500 User Manual

Wacker Neuson GH 3500
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Maintenance GH 3500
26
7.6 Checking / cleaning / replacing the spark plug
f Remove the spark plug connector.
f Remove the spark plug with a spark plug wrench.
f Clean the electrodes with a wire brush.
f Check the isolator (2) – if damaged, replace the spark plug.
f Check and adjust the electrode gap (1) – see chapter Technical data for the
gap.
f Insert the spark plug and tighten it with a torque wrench.
WARNING
Hot exhaust!
Touching it can cause burns.
Only remove the spark plug when the engine has cooled down.
Torque [Nm] Spark plug
15
New spark plug
25
Used spark plug
CAUTION
A loose spark plug can damage the engine.
Always tighten the spark plug.
1
2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson GH 3500 and is the answer not in the manual?

Wacker Neuson GH 3500 Specifications

General IconGeneral
BrandWacker Neuson
ModelGH 3500
CategoryPortable Generator
LanguageEnglish

Related product manuals