Operation 5
BA TH412 * 06/2017 * 4512_5-13_2_Opt_Hydr_en.fm
5-89
Operate additional hydraulic connections on the mast (4th control circuit)
Move the rocker switch 47 to "position 0".
The standard hydraulic connections are in
operation.
Move the rocker switch 47 to "position I."
The additional hydraulic connections are in
operation.
If the additional hydraulic connections are switched on:
Move control lever 6 toward (L):
The rear connection is the pressure side, the front
connection is the return.
Move control lever 6 toward (R):
The front connection is the pressure side, the rear
connection is the return.
Fig. 107
R
L
6
47
0
I