Operation 5
BA TH412 * 06/2017 * 4512_5-13_5_Opt_Sonst_en.fm
5-107
Water penetrating into the controls of the central
lubrication system can destroy them.
► Always close the cover correctly, otherwise water can
penetrate into the controls and destroy them.
Pressing button A on the side of the pump starts
intermediate lubrication at any given time if the ignition is
switched on. This also serves as a functional check.
► The pump then immediately starts with the lubrication
cycle. The lubrication or break time that has elapsed
so far or that has been saved is reset and starts over
again.
► A lubrication system malfunction can also be reset by
pressing the intermediate lubrication switch, and the
pump restarts lubrication.
Setting lubrication and break times
Observe the original Operator’s Manual of the central
lubrication system!