7-10
BA TH412 * 06/2017 * 4512_7-1_Hinweise_en.fm
7 Maintenance
Inspection after 500 operating hours
NOTICE
The maintenance and inspection personnel must have
specialized knowledge about the maintenance and
inspection work on the machine.
Observe the Operator’s Manual of the engine.
Information
This inspection is performed once after the first 500
operating hours. If the machine does not reach 500
operating hours during its first year of operation, perform
this inspection once 12 months after putting the machine
into operation.
Work to be performed by an authorized service center after 500 operating hours
Check the gearbox, engine and hydraulic system for leaks
Check the engine and hydraulic oil radiator for dirt
Check the coolant level and antifreeze
Check the tension and condition of the V-belt
Check the routing of the hoses and pipes
Check the piston rods of the hydraulic cylinders
Check the air filter hose
Check the routing of Bowden cables and electric cables
Retighten all bolts; pay particular attention to the engine mountings, axle mountings and cardan shaft
Check the rubber buffers on the engine mountings
Check the battery acid level