EasyManua.ls Logo

WAGNER EvoMotion 20-30 - Assembly and Commissioning; Training of Assembly;Commissioning Personnel; Storage Conditions; Installation Conditions

WAGNER EvoMotion 20-30
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating manual Piston Pump EvoMotion 20-30
6 Assembly and Commissioning
Order number 2333553 | Edition 09/2020 27
6 ASSEMBLY AND COMMISSIONING
6.1 TRAINING OF ASSEMBLY/COMMISSIONING PERSONNEL
The assembly and commissioning personnel must have the technical skills to safely
commission the device.
When assembling, commissioning and carrying out all work, read and follow the
operating manuals and safety regulations for the additionally required system
components.
A skilled person must check to ensure that the device is in a reliable state after it is
assembled and commissioned.
6.2 STORAGE CONDITIONS
Until the point of assembly, the device must be stored in a dry location, free from vibrations
and with a minimum of dust. The device must be stored in closed rooms.
Die Lufttemperatur am Lagerort muss in einem Temperaturbereich zwischen -20°C und
+60°C; -4°F und +140°F liegen.
The relative air humidity at the storage location must be between 10 and 95% (without
condensation).
6.3 INSTALLATION CONDITIONS
The air temperature at the installation site must be in a range between 4°C and 40°C; 39°F
and 104°F.
The relative air humidity at the installation site must be between 10 and 95% (without
condensation).
6.4 TRANSPORTATION
The pump can be moved on a trolley or manually without lifting equipment or a crane.
6.5 ASSEMBLY AND INSTALLATION
WARNING
Inclined ground!
Risk of accidents if the device rolls away/falls.
4 Place device on level ground and secure it.
4 If the floor is inclined, position the feet of the trolley towards the gradient.
4 Secure the trolley.
Info
Ensure that the national explosion prevention rules and regulations are observed when
setting up the device.
This pump can be used as part of a spraying system for Airless or AirCoat applications.
Individual supplement components for this pump can be found in the Wagner accessories
catalogue, or can be put together with a spraypack configurator. The nozzles must be
selected according to the spray gun operating manual. In the case of spraypack orders, the
pumps (1) are already pre-mounted on a trolley (6) or on a frame at the factory.