English
14 © Wagner Spray Tech. - All Rights Reserved
Cleanup (continued)
Cleaning the Regulator
Note: Removing and cleaning the regulator is necessary
to keep your sprayer from clogging or from producing an
irregular spray pattern.
To Clean the Regulator
1. Remove the paint hose (a) from the nozzle and remove
the cover (b).
2. Pull out the red catch and remove the pressure reducer
(c).
3. Remove the valve (d) and clean thoroughly.
4. Clean the openings in the pressure reducer using a brush
and water. Replace the valve removed in step 3.
5. Replace the pressure reducer into the spray nozzle and
secure with the red catch.
Note: Make sure the red seal (e) is in place prior to
reinstallation.
6. Place the cover onto the spray nozzle and replace the
paint hose.
a
b
c
d
1
2
e
1
2
4
6
3
5