Material connection:
Connect the pump's suction hose (on the underside) to the suction manifold. Connect it to
the material hose's delivery manifold (on the upper side). Use  exible hoses to absorb the
pump's vibrations. Ensure that the hoses are not mechanically stressing the pump. Never
directly connect the pump to rigid pipes.
For pumps installed in areas subject to explosion hazards, all hoses and pipes must be
made of conductive material and must be grounded.
Install a suction  lter on the suction hose. This prevents particles, that are large enough to
damage the internal parts of the pump, from entering. Refer to the Technical Data chapter
to verify the maximum size of solids that can be pumped.
Air suction  lter
Material delivery valve
Material return valve
Air pressure regulator
Suction hose
Air cut-o valve
Suction manifold
Delivery manifold
Material hose
Safety valve