27
OPERATING MANUAL
VERSION 05/2017 ORDER NUMBER DOC 2354920
SPRINT XE
28 LED display: "High Voltage"
– Lights up yellow. The high voltage is selected and can be adjusted using rotary
controller 24
29 Push button: "Current Limitation"
– To activate the function, the current limitation is set with the control dial 24 and is
indicated in the LED display 19
– Adjusting range: 5–120 μA
– Resolution: 1 μA
30 LED display: "Current Limitation"
– Lights up yellow. The current limitation is selected and can be adjusted using the
rotary controller (24).
31 Push button: "Characteristic Slope"
– To switch the characteristic slope
– Display with LED 32
32 LED display: "Characteristic Slope"
– Lights up green
– Lower LED characteristic curve,  at
– Middle LED characteristic curve, medium
– Upper LED characteristic curve, steep
33 Illuminated display: "Powder Quantity"
– Lights up green
– Display range: 0–100 %
– Resolution: 3.33 %
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
34 Illuminated display: "Total Air Volume"
– Lights up green
– Display range: 2–6 m³/h
– Resolution: 0.2–0.5 m³/h
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
35 Illuminated display: "Atomizing, Ionizing and Tribo Air Volume"
– Lights up green
– Display range: 0.1–4 m³/h
– Resolution: 0.1–1.0 m³/h
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)