EasyManua.ls Logo

Waldorf pulse 2 - MIDI, Clock, and Transmission Settings

Waldorf pulse 2
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Additional Settings
41 Pulse 2 User Manual
se 2 receives MIDI properly, set MIDI Channel
to any other value than omni.
MIDI Thru OFF / ON
Activates the MIDI Thru function of the MIDI Out port.
Incoming MIDI data will be automatically sent via MIDI
Out port to connected MIDI devices. Additionaly, the
Pulse 2 will send out its own data via MIDI Out.
Clock AUTO / INTERN / EXTERN
Determines how the Pulse 2 reacts on incoming MIDI
Clock messages:
AUTO means that the Pulse 2 automatically
syncs to incoming MIDI Clock if it is sent to it
by an external device like a sequencer or
drum machine. If there is no MIDI Clock
present, the Pulse 2 generates its internal
tempo base. This is the recommended setting
that works in almost all situations.
INTERN means that the Pulse doesn’t react
on incoming MIDI Clock nor does it send
MIDI Clock. The Pulse 2 only syncs to its
own tempo base that is set by ARP Tempo.
EXTERN means that the Pulse 2 syncs to in-
coming MIDI clock only.
TX Arp Clock OFF / ON
Determines whether Arpeggiator tempo is sent out as
MIDI clock data over USB MIDI and MIDI.
TX Arp Notes OFF / ON
Determines whether Arpeggiator notes are sent by the
Pulse 2 over USB MIDI and MIDI.
TX Parameter OFF / CC / SYSEX / CC+SYS
Determines how Real-Time Sound Parameter Changes
are sent by the Pulse 2.
If OFF is selected, no data is sent.
If CC is selected, only controller messages are sent.
Parameters without a dedicated controller are not
sent at all.
If SYSEX is selected, all Sound parameters are sent
as system exclusive messages. The disadvantage is
a larger amount of data that is transferred.