User’s Manual Pulse • PulsePlus
69
CV/Gate Interface Parameter Dump Request
Byte No Value Parameter Description/Range
0 $F0 Exclusive Status SysEx transfer start
1 $3E Manufacturer ID Waldorf Electronics GmbH
2 $0B Model ID Pulse ID
3 0...126 Device ID Equivalent to the global parameter device ID
4 $49 Function Code Dump type CV/Gate interf. param. dump request
5 $F7 EOX End of SysEx message
Controller Dump Request
Byte No Value Parameter Description/Range
0 $F0 Exclusive Status SysEx transfer start
1 $3E Manufacturer ID Waldorf Electronics GmbH
2 $0B Model ID Pulse ID
3 0...126 Device ID Equivalent to the global parameter device ID
4 $4B Function Code Dump type controller dump request
5 $F7 EOX End of SysEx message
Polyphony Parameter Dump Request
Byte No Value Parameter Description/Range
0 $F0 Exclusive Status SysEx transfer start
1 $3E Manufacturer ID Waldorf Electronics GmbH
2 $0B Model ID Pulse ID
3 0...126 Device ID Equivalent to the global parameter device ID
4 $4A Function Code Dump type polyphony parameter dump request
5 $F7 EOX End of SysEx message