4. Operation Instructions for Administrators
1402 "One-Timer"
4.1 Important hints for Administrators
- With service key you can always open the lock
- With every openeing the code is deleted
- Service key can only be removed in closed position
- Service key is provided with key numbers
- For security reasons please keep the number of service keys at a minimum and keep it
in a safe place
4.2 QUICK-RESET
Insert service key into barrel
and turn it 90° to the left
1.
1
2
2. Open the lock
- 7 -