Page 32
2.4.9 K-Series Kabin Pak – Combi (KC)
KC90KC70MODEL
Nominal kW
Heat Output Btu/hr
Nominal kW
Heat Input Btu/hr
Burner
Head
Secondary Air Damper
Flue mm
Diameter in
Flue Gas Temp °C
Smoke Bacarach
14.0
48,000
17.0
58,000
20.5
70,000
20.5
70,000
22.8
78,000
26.4
90,000
15.3
52,150
18.4
62,600
22
75,000
22
75,000
24.4
83,175
28
95,550
RDB 2.2 15-21 RDB 2.2 21-26
T1SH T2SH
B N/A
100 or 125
4 or 5
100 or 125
4 or 5
180 190 200 200 210 215
0 0
Kerosene Settings
Nozzle make
size
Oil Pump bar
Pressure psi
Max CO2 %
Approx Fuel litres/h
Flow Rate gals/h
Flow Connection
Return Connection
Water litres
Content gals
Boiler Weight Dry kg
Boiler Weight Wet kg
SEDBUK Efficiency %
Factory Settings
Danfoss 60°ES
0.5 0.5 0.6
Danfoss 60°ES
0.6 0.65 0.75
7.0
100
9.0
131
8.0
116
8.0
116
8.0
116
7.0
100
11.5 11.5 11.5 11.5 11.5 11.5
1.65
0.36
1.98
0.44
2.35
0.52
2.35
0.52
2.65
0.58
2.98
0.65
22mm Copper 22mm Copper
70
15.4
128
198
82.8 82.8
Highlighted in Bold
70
15.4
128
198
Domestic Hot Water (DHW) Production
Minimum Inlet Dynamic Pressure bar
for Maximum DHW Flow Rate psi
Maximum Achievable
DHW Flow Rate
Maximum Recommended litres/m
DHW Flow Rate gals/m
Factory Set litres/m
DHW Flow Rate gals/m
Minimum litres/m
DHW Flow Rate gals/m
DHW Temperature Rise
(at Maximum Output)
Pressure Relief bar
psi
Cold Water Mains
Inlet Connection
DHW Outlet Connection
1.8
26
1.8
26
Unrestricted Unrestricted
18
4.0
24
5.3
18
4.0
18
4.0
2.5
0.55
2.5
0.55
32°C @ 18 litres/min
for 120 litre draw-off
32°C @ 24 litres/min
for 120 litre draw-off
3
43.5
3
43.5
Minimum 15mm
Unrestricted
Minimum 15mm
Unrestricted
22mm Copper 22mm Copper
22mm Copper 22mm Copper
Gas Oil Settings (see note below)
Nozzle make
size
Oil Pump bar
Pressure psi
Max CO2 %
Approx Fuel litres/h
Flow Rate gals/h
Danfoss 60°S
— 0.4 0.5
Danfoss 60°S
0.65 0.6
—
—
12.0
174
11.0
159
8.0
116
11.0
159
— 12.0 12.0 12.0 12.0
—
—
1.72
0.38
2.30
0.51
2.65
0.58
2.76
0.61
0.5
11.0
159
12.0
2.30
0.51
Note: With Class D gas oil the flue MUST exhaust at more than 2m above the surrounding
ground level. The low-level flue supplied as standard with all Kabin Pak models is
NOT suitable for Class D gas oil. Alternative options are available – please contact
Warmflow.