DE
DE Constant
Speed
ME
CPP Con-
stant Speed
ME
CPP Variable
Speed
Wärtsilä 16V46F
120012001200kWCylinder output
600600600rpmEngine speed
Starting air system (Note 5)
300030003000kPaPressure, nom. (PT 301)
150015001500kPaPressure at engine during start, min. (20°C)
300030003000kPaPressure, max. (PT 301)
180018001800kPaLow pressure limit in air vessels
16.016.016.0Nm
3
Consumption per start at 20°C (successful start)
19.019.019.0Nm
3
Consumption per start at 20°C, (with slowturn)
Notes:
At ISO 15550 conditions (ambient air temperature 25°C, LT-water 25°C) and 100% load. Flow tolerance 5%.Note
1
At ISO 15550 conditions (ambient air temperature 25°C, LT-water 25°C). Flow tolerance 5% and temperature tolerance
20°C.
Note
2
At ISO 15550 conditions (ambient air temperature 25°C, LT-water 25°C) and 100% load. Tolerance for cooling water heat
10%, tolerance for radiation heat 30%. Fouling factors and a margin to be taken into account when dimensioning heat ex-
changers.
Note
3
According to ISO 15550, lower calorific value 42700 kJ/kg, with engine driven pumps (two cooling water + one lubricating
oil pumps). Tolerance 5%. The fuel consumption at 85 % load is guaranteed and the values at other loads are given for in-
dication only. Consumption values in DE constant speed are valid for D2/E2 IMO cycles. If Wartsila NOR is installed SFOC
consumption values may vary. Please contact Wärtsilä to have further informations.
Note
4
At manual starting the consumption may be 2...3 times lower.Note
5
ME = Engine driving propeller, variable or constant speed
DE = Diesel-Electric engine driving generator at constant speed
Subject to revision without notice.