WL350Manual Page13–Revision11‐21‐2018
SERVICEREQUIREMENTS
WARNING!Readandunderstandthecontentsofthismanualbeforeattemptingtoservice
WL350WaterTreatmentSystem.Failuretofollowtheinstructionsinthismanualcould
resultindeath,seriouspersonalinjury,orseverepropertydamage.Onlytrainedand
qualifiedtechniciansshouldattempttoinstall,maintain,orserviceWaterlogicEquipment.
1. Visuallyinspectallelectricalandwaterconnectionsforsignsofwearordamage.
DANGER!HIGHVOLTAGEELECTRICALHAZARD.Unplugbeforeinspectionandservice.
2. WaterlogicrecommendschangingtheUVLampevery6months.
WARNING!ULTRAVIOLETRADIATION.Protectyourskinandeyesagainstultravioletrays.
NeverlookdirectlyatanoperatingUVlight.DisconnectbeforeremovingUVLamp.
CAUTION!UVLAMPSAREHAZARDOUS.LampsareconsideredHazardousWasteandmust
bedisposedofaccordingly.RefertoProductMSDSsheetfordetails.
3. CleantheSpiralQuartzSleevethatsurroundstheUVLampwithanon‐abrasivecloth,descaling
solution,orultrasonicbathifneededwhenchangingUVLamps.
CAUTION!UVSYSTEMISFRAGILE.NeverhandletheUVlamporQuartzSleevewithbare
hands.UVLampandquartzsleevemustbefreeofoilsandcontaminantstoensureproper
operation.Useasoftnon‐abrasiveclothtoclean.
4. SanitizetheColdTankperinstructionsinthepre‐installationprocedures.
5. Cleanandsanitizeexternalsurfacesoftheunit.Usesoapandwaterorchemicalsthatare
compatiblewithABSplasticandwillnotdamageordegradetheproductsurfaces.
6. RemoveandcleantheFaucet.Replaceasneeded.
WARNING!SANITIZERMAYCONTAINHAZARDOUSCHEMICALS.Useofproperpersonal
protectiveequipmentsuchasrubberglovesandeyeprotectionisrequired.