WL350Manual Page44–Revision11‐21‐2018
PRE‐INSTALLATIONPROCEDURES
DANGER!ELECTRICALSHOCKHAZARD.
Onlyqualifiedpersonnelwhohavereadandunderstandthisentiremanualshouldattemptto
install,orservicethisunit,failuretodosocouldresultindeathorseriousinjury.DONOTplug
intoanelectricalsupplyuntilspecificallyinstructed.
WARNING!ALWAYSSANITIZEBEFOREUSE.
Sanitizebeforeusetoeliminateanypotentialmicrobiologicalcontaminates.
RedCompressor/HeaterSwitchmustbeintheO=OFFpositionwhiletheHot
Tankisempty.DamagecouldoccurwithinoneminuteandthetwoHotTank
OverloadDevices(HighSafetyLimit)requiremanualresetifheateristurned
onwithanemptyHotTank.
CAUTION!DRIPTRAYDRAIN.
Ifyouintendtoprovideadriptraydrainforyourcustomer,beawarethatyou
willbecalledmultipletimespermonthtoserviceandunclogthetubing
leadingawayfromthedriptraytodrain.Userswillclogthedrainwithpaper
clips,erasers,napkins,teabags,gum,andvariousotherintendeditems.
Waterlogicrecommendsyouestablishaminimumofweeklyvisitstothe
machineforcleaningofthedriptraydrain.
MaterialsNeeded:
PersonalProtectiveEquipment.RubberorNitrileSafetyGlovesandProtectiveEyewear
PhillipsScrewdriver
TemperatureGauge
WaterPitcherorContainertocollectwaterfromthefaucet
16Liter(5gallon)containerordrainbasin
Sanitizer‐HouseholdBleach(5.25%SodiumHypochlorite)orCitricAcidBasedCleaner
¼”PlasticTubing,atleast4feetinlength,andassorted¼”quickconnectfittings
TDSMeterandTestStripsformeasuringchlorine–Optional
SanitizingCartridge
1. UnpacktheWaterlogicWL350WaterTreatmentSystemsandcheckexteriorfordamage.
Sanitizing
SanitizeusingaHouseholdBleach(5.25%SodiumHypochloritesolution)orotherapproved
cleanerthroughoutthecoldandsparklingwatercircuits.Followallinstructionsonthesanitizer
andflushwithfreshwaterthroughthefaucetuntilodorandtasteisacceptable.