What does error Er1 mean on Watson Marlow Pumps 620RE?
- DDana VincentSep 7, 2025
If your Watson Marlow Pumps Water Pump displays the error code Er 1 (FRAM corruption), try resetting the pump by switching the power off and then on again.
What does error Er1 mean on Watson Marlow Pumps 620RE?
If your Watson Marlow Pumps Water Pump displays the error code Er 1 (FRAM corruption), try resetting the pump by switching the power off and then on again.
What does error Er2 mean on Watson Marlow Pumps 620RE Water Pump?
If your Watson Marlow Pumps Water Pump displays the error code Er 2 (FLASH write error during drive update), try resetting the pump by switching the power off and then on again.
What does error Er3 mean on Watson Marlow Pumps 620RE Water Pump?
If your Watson Marlow Pumps Water Pump displays the error code Er 3 (FLASH corruption), try resetting the pump by switching the power off and then on again.
What does error Er4 mean on Watson Marlow Pumps Water Pump?
If your Watson Marlow Pumps Water Pump displays the error code Er 4 (FRAM shadow error), try resetting the pump by switching the power off and then on again.
What does error Err50 mean on Watson Marlow Pumps 620RE Water Pump?
If your Watson Marlow Pumps Water Pump displays the error code Err50 (Communication error), try resetting the pump by switching the power off and then on again.
Brand | Watson Marlow Pumps |
---|---|
Model | 620RE |
Category | Water Pump |
Language | English |
Best practices for pump siting, airflow, temperature, and emergency stop setup.
Lists essential guidelines and prohibitions for pump installation and tubing.
Explains the wiring procedure for the NEMA module and PROFINET connections.
Lists and defines the electrical parameters for external interface signals.
Accesses menu options for configuring pump security, including keypad lock and PIN protection.
Accesses menu options for configuring general pump parameters like Auto Restart and flow units.
Configures pump control parameters such as speed limit and run hours.
Guides configuring pump inputs for leak detection, pressure, and start/stop signals.
Instructions for starting, stopping, and adjusting the flow rate in Manual mode.
Step-by-step guide to calibrate the pump's flow rate measurement.
Guides setting up PROFINET parameters like DHCP, IP address, subnet, and gateway.
Step-by-step instructions for creating or editing dispense recipes.
Guides for creating or editing batches, including naming and parameter setup.
Instructions on initiating and managing the dispensing process, including start, stop, and info.
Guides for configuring sensor types, input assignments, and units.
Lists common error codes, their conditions, and suggested troubleshooting actions.
Detailed instructions for removing and refitting the 620R and 620RE pumpheads.
Step-by-step guide for replacing continuous tubing in 620R and 620L pumpheads.