BlueCool S Series 10 Overview of Programming Functions
33
10.2 Description of programming codes
10.2.1 Operating level and Setting levels 1, 2 and 3
NOTE
The parameters from Parameter No. 2 can only
be displayed or set after the access code has
been entered.
Table 3 Parameter list of programming functions for operating level and setting level 1
Display Parameter Value Range Assignment Factory Set-
ting
See Page
Operating level
b Fan speed 1 to 5, A 1 = Speed 1
...
5 = Speed 5
A = Automatic
A36
E Evaporator temperature - Display of evaporator
temperature in °C or °F
-36
Setting level 1
F Operating mode 01, 02, 03, 07 01 = cooling only
02 = heating only
03 = automatic switching
between cooling and
heating
07 = Dehumidification
03 36
U Operating voltage - Display of operating voltage
in V
-36
Fd. Number of dehumidifica-
tion cycles in 24 hours,
Operating mode F07
00 to 03 01 = 1 cycle
02 = 2 cycles
03 = 3 cycles
01 36
hd. Heating time in dehu-
midification cycle
01 to 99 01 = 1 min.
...
99 = 99 min.
01 36
cd. Cooling time in dehu-
midification cycle
01 to 99 01 = 1 min.
...
99 = 99 min.
01 36