10 Overview of Programming Functions BlueCool S Series
34
Table 4 Parameter list of programming functions for Setting level 2
Display Parameter Value Range Assignment Factory Set-
ting
See Page
Setting level 2
0. Undervoltage switch-off 180 to 210 - 195 37
1. Activation or deactiva-
tion of IR remote control
00 to 01 00 = deactivated
01 = activated
00 37
2. Fan type (AC, EC, elec-
tronic silencer)
00 to 02 00 = AC
01 = EC
02 = electronic silencer
00 37
3. Thermostat-controlled
fan or permanently
switched-on fan
00 to 01 00 = thermostat-controlled
01 = permanent
00 37
b5. Fan speed “5” 25 to 100 0 = 0%
100 = 100%
100 37
b4. Fan speed “4” 25 to 100 0 = 0%
100 = 100%
60 37
b3. Fan speed “3” 25 to 100 0 = 0%
100 = 100%
50 37
b2. Fan speed “2” 25 to 100 0 = 0%
100 = 100%
40 37
b1. Fan speed “1” 25 to 100 25 = 0%
100 = 100%
30 37
c. Access code for setting
levels
00 to 99 - 64 38