BlueCool S Series 10 Overview of Programming Functions
35
Table 5 Parameter list of programming functions for Setting level 3
Display Parameter Value Range Assignment Factory Set-
ting
See Page
Setting level 3
u. Temperature unit 00 to 01 00 = °C
01 = °F
00 39
0. Switch-off temperature,
compressor cooling
(minimum)
-4 to 15 °C
24 to 59 °F
x=x°C/°F -2°C
28 °F
39
1. Switch-off temperature,
compressor cooling
-4 to 15 °C
24 to 59 °F
x=x°C/°F 0°C
32 °F
39
2. Switch-on temperature,
compressor cooling
2 to 18 °C
35 to 65 °F
x=x°C/°F 4°C
39 °F
39
3. Switch-off temperature,
compressor heating
30 to 55 °C
86 to 131 °F
x=x°C/°F 52°C
126 °F
39
4. Switch-on temperature,
compressor heating
27 to 50 °C
81 to 122 °F
x=x°C/°F 48°C
118 °F
39
5. Switch-on/switch-off
hysteresis compressor
0.1 to 0.8 °C
0.2 to 1.4 °F
x=x*0.1°C/°F 0.8°C
1.4 °F
40
6. Correction value of dis-
played room tempera-
ture
-5.5 to 5.5 °C
-9.9 to 9.9 °F
x=x*0.1°C/°F 0°C
F
40
7. Maximum time during
which the evaporator
temperature may be
below the “Switch-off
temperature, compres-
sor cooling"
000 to 999 sec x = x s 300 40
8. Firmware version - Display of control unit type - 40