Thermo Top C / Thermo Top E Technical data
53
* May only be operated with diesel / PME mixture containing < 50% PME.
Heater Operation Thermo Top C - B Thermo Top C - D Thermo Top C - D
EC approval mark e1
Type Water heater with evaporator-type burner
Heat output Full load
Part load
5.2 kW
2.5 kW
Fuel Petrol Diesel Diesel/PME
Fuel consumption Full load
Part load
0.70 l/h
0.34 l/h
0.61 l/h
0.30 l/h
Nominal voltage 12 V
Operating voltage range 10,5 ... 15 V
Nominal power consumption without circulation pump
(without vehicle fan)
Full load
Part load
28 W
18 W
Perm. ambient temperature:
Heater: - Operation
- Storage
Metering pump: - Operation
-40° ... +60°C
-40° ... +120°C
-40° ... +20°C
-40° ... +60°C
-40° ... +120°C
-20° * ... +20°C
Perm. operating pressure (heat carrier) 0.4 ... 2.5 bar
Capacity of the heat exchanger 0.15 l
Minimum capacity of the circulation 4.00 l
Minimum flow rate for the heater 250 l/h
CO
2
in the exhaust gas (perm. function range) 8 ... 12.0% by vol.
Heater dimensions
(tolerance
± 3 mm)
Width 214 mm
Height 106 mm
Weight 168 mm
Weight 2.9 kg