- 19 -
Code
Name
Range
Default
Feature
RAM
address
F7.04
Keypad Display Value 2
(Running Status)
LED Ones Place: 1st Display
Value
0: PID Feedback Value
1: PLC Stage
2: Reserved
3: Feedback Speed
4: Reserved
5: Reserved
6: Reserved
7: Reserved
8: Reserved
9: Currently Power-on
Period
A: Currently Running
Period
B: Reserved
C: Reserved
D: Reserved
E: Main Frequency Source
X
F: Auxiliary Frequency
Source Y
LED Tens Place: 2nd Display
Value
LED Hundreds Place: 3rd
Display Value LED
Thousands Place: 4th
Display Value
0
0704
F7.05
Keypad Display Value 1
(Stop Status)
Same as F7.03
3421
0705
F7.06
RPM Display
Coefficient
0.0 to 5000.0%
100.0%
0706
F7.07
IGBT Temperature
0 to 100
-
0707
F7.08
Rectifier Temperature
0 to 100
-
0708
F7.09
Accumulated Running
Time
0 to 65535h
-
0709
F7.10
Product Item Number
-
-
070A
F7.11
Software Version
-
-
070B
F7.12
Reserved
070C
F7.13
Accumulated Power-on
Time
0 to 65535h
-
070D
F7.14
Accumulated Power
Consumption
-
070E
F8.00
Set Frequency of Jog
Run
0.00 to F0.10
5.00Hz
0800