5.3 Main Error Codes and Solutions
Overcurrent
during
acceleration
There is grounding or short circuit
in the output circuit of the
controller
Eliminate peripheral faults
and check whether there is a
short circuit at the motor end
Acceleration time is set too short
Increase acceleration time
The controller model is selected
improperly(with too small power)
Select the controller that
matches the motor power
and load conditions
Overcurrent
during
deceleration
There is grounding or short circuit
in the output circuit of the
controller
Eliminate peripheral faults
and check whether there is a
short circuit at the motor end
Deceleration time is set too short
Increase deceleration time
Overcurrent at
constant speed
There is grounding or short circuit
in the output circuit of the
controller
Eliminate peripheral faults
and check whether there is a
short circuit at the motor end
Controller model is too small
Select the controller that
matches the motor power
and load conditions
Overvoltage
during
acceleration
Input voltage is too high
Adjust input voltage to a
proper range
Acceleration time is set too short
Increase acceleration time
No braking unit and braking
resistor installed
Install braking unit and
braking resistor
Overvoltage
during
deceleration
Input voltage is too high
Adjust input voltage to a
proper range
Deceleration time is set too short
Increase deceleration time
No braking unit and braking
resistor installed
Install braking unit and
braking resistor
Overvoltage at
constant speed
Input voltage is too high
Adjust input voltage to a
proper range
The input voltage is not within
the specified range
Adjust input voltage to a
proper range
The input voltage is not within
the specified range
Adjust input voltage to a
proper range
Abnormal bus voltage detection;
abnormality of rectifier bridge,
snubber resistor, drive board and
control board
Seek for technical support
Load is too large or motor is stuck
Reduce load and check motor
and mechanical condition
Controller model is too small
Select the controller that
matches the motor power
and load conditions
The motor overload protection
parameters (FA.01-FA.02) are not