EasyManua.ls Logo

WEG CFW-11 - Preliminary Recommendations

WEG CFW-11
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quick Parameter Reference, Faults and Alarms
Crane Horizontal Motion | 8
Parameter
Description Adjustable Range
Factory
Setting
User
Setting
Properties
Groups
Page
P1025
Limit Switches Configuration
0 = Without Limit Switches
1 = Forward Slowdown via DI7 and
Reverse Slowdown via DI8
2 = Forward Slowdown via DI7 and
Stop Forward via DI8
3 = Reverse Slowdown via DI7 and
Stop Reverse via DI8
4 = Forward Slowdown via DI9 and
Forward Slowdown via DI10
5 = Forward Slowdown via DI9 and
Stop Forward via DI11
6 = Forward Slowdown via DI10 and
Stop Reverse DI12
7 = Forward Slowdown via DI9,
Forward Slowdown via DI10, Stop
Forward via DI11 and Stop Reverse
via DI12
0
cfg
50
29
P1026
Motor Rotation Direction Inversion
0 = Off
1 = On
0
cfg
50
22
P1027
Motor Demagnetization Time
0 to 65000 s
600 s
50
23
P1028
Speed Hysteresis for Inverter in
Torque Limit Detection
0.0 to 50.0 %
7.5 %
50
48
P1029
Inverter in Torque Limit Fault (F775)
Delay Time
0.00 to 650.00 s
0.75 s
50
48
P1030
Speed Reference via Communication
Networks
0.0 to 1020.0 Hz 0.0 Hz
50
26
P1031
Speed Reference 1 0.0 to 1020.0 Hz 6.0 Hz
50
26
P1032
Speed Reference 2 0.0 to 1020.0 Hz 60.0 Hz
50
27
P1033
Speed Reference 3 0.0 to 1020.0 Hz 0.0 Hz
50
27
P1034
Speed Reference 4 0.0 to 1020.0 Hz 0.0 Hz
50
28
P1035
Speed Reference 5 0.0 to 1020.0 Hz 0.0 Hz
50
28
P1036
Dwell Time at Speed Reference 1
0.00 to 650.00 s
0.50 s
50
28
P1038
Current Threshold for Lightweight
Detection
0.0 to 3000.0 A
10.0 A
50
37
P1039
Speed Threshold for Lightweight
Detection Enabling
0.0 to 1020.0 Hz 0.0 Hz
50
38
P1041
Brake Release Frequency Threshold
0.0 to 1020.0 Hz
4.0 Hz
50
40
P1043
Brake Release Current Threshold
0.0 to 3000.0 A
0.0 A
50
40
P1045
Brake Release Torque Threshold 0.0 to 350.0 % 0.0 %
50
40
P1046
Brake Response Time to Release 0.00 to 650.00 s 0.10 s
50
41
P1047
Inhibition of the Brake Closing during
a Forward/Reverse Command
Transition
0 = Off
1 = On
0
50
41
P1048
Brake Closing Frequency Threshold 0.5 to 1020.0 Hz 2.5 Hz
50
41
P1049
Delay Time for Brake Closing 0.00 to 650.00 s 0.00 s
50
41
P1050
Time to Enable a new Command to
Brake Release
0.10 to 650.00 s 0.20 s
50
42
P1052
Momentary Overload Current
Threshold
0.0 to 3000.0 A
40.0 A
50
45
P1053
Momentary Overload Detection Delay
Time
0.00 to 650.00 s
1.00 s
50
45
P1054
Momentary Overload Alarm (A770)
Delay Time
0.00 to 650.00 s 1.00 s
50
46
P1058
Number of Consecutive Alarms for
Improper Fault (F777)
0 to 10
3
50
48
P1059
Period of Time for Improper Fault
(F777)
0 to 65000 s
120 s
50
49

Other manuals for WEG CFW-11

Related product manuals