EasyManua.ls Logo

WEG CFW-11 - Safety Warnings on Product

WEG CFW-11
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quick Parameter Reference, Faults and Alarms
Crane Horizontal Motion | 7
QUICK PARAMETER REFERENCE, FAULTS AND ALARMS
Parameter
Description Adjustable Range
Factory
Setting
User
Setting
Properties
Groups
Page
P1010
Crane Horizontal Motion Version 0.00 to 10.00
ro
50
50
P1011
Last Alarm 0 to 999 ro
50
50
P1012
Last Alarm Date 01.01 to 31.12 ro
50
50
P1013
00.00 to 23.59
ro
50
51
P1014
0 to 999
ro
50
50
P1015
01.01 to 31.12
ro
50
50
P1016
00.00 to 23.59
ro
50
51
P1017
0 to 999
ro
50
50
P1018
01.01 to 31.12
ro
50
50
P1019
Third Alarm Time 00.00 to 23.59 ro
50
51
P1020
1
Bit 0 = General Enabled
Bit 1 = Running (RUN)
Bit 2 = Rotation Direction
Bit 3 = LOC / REM
Bit 4 = Fault Condition
Bit 5 = Undervoltage
Bit 6 = Alarm Condition
Bit 7 = Load Forward Command
Bit 8 = Load Reverse Command
Bit 9 = Brake Release Command
Bit 10 to 15 = Reserved
ro
50
51
P1021
2
Bit 0 = Lightweight Operation
Bit 1 = Coast to Stop
Bit 2 = Fast Stop
Bit 3 = Emergency Stop
Bit 4 = Stop by Simultaneous
Commands
Bit 5 = Forward Slowdown
Bit 6 = Reverse Slowdown
Bit 7 = Stop Forward
Bit 8 = Stop Reverse
Bit 9 = Momentary Overload Alarm
Bit 10 = Reserved
Bit 11 = Reserved
Bit 12 = Inverter in Torque Limit
Bit 13 = Improper Operation
Bit 14 = Reserved
Bit 15 = Reserved
ro
50
52
P1022
Communication Network Control
Word
Bit 0 = Load Forward
Bit 1 = Load Reverse
Bit 2 to 15 = Reserved
0 rw
50
29
P1023
Speed Reference Control
Configuration
0 = Speed Reference via
Electronic Potentiometer (EP)
1 = One Speed Reference via
Digital Input DI4
2 = Two Speed References via
Digital Input DI4
3 = Three Speed References via
Digital Input DI4 and DI5
4 = Four Speed References via
Digital Input DI4 and DI5
5 = Five Speed References via
Digital Input DI4, DI5 and DI6
6 = Speed Reference via Analog
Input AI1 (Step Less)
7 = Speed Reference via
Communication Networks
2 cfg
50
25
P1024
Enable use of a Filter in the Forward
and Reverse Commands
0 = Off
1 = On
0
50
22

Other manuals for WEG CFW-11

Related product manuals