WEG SSW900 Series User Manual

WEG SSW900 Series
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Motors | Automation | Energy | Transmission & Distribution | Coatings
Anybus PROFINET IO
SSW900-CPN-IO-N
User’s Guide
Question and Answer IconNeed help?

Do you have a question about the WEG SSW900 Series and is the answer not in the manual?

WEG SSW900 Series Specifications

General IconGeneral
TypeSoft Starter
Input Frequency50/60 Hz
Output CurrentSame as Current Range
Control MethodVoltage ramp, current limit, torque control
Protection FeaturesOverload, overcurrent, phase loss, overtemperature, short circuit
Communication ProtocolsModbus RTU, Profibus DP, Ethernet/IP
Bypass ContactorIntegrated (depending on model)
Enclosure RatingIP20
HumidityUp to 95% non-condensing
DimensionsVaries by model
WeightVaries by model

Summary

Interface Description

Anybus PROFINET IO Accessory

Details the specific Anybus PROFINET IO communication module and its supplied items.

PROFINET Network Installation

IP Address Configuration

Explains IP addressing methods (parameter/DHCP) and device naming for PROFINET.

Status Monitoring (S Status)

S5.1 Status Word

Explains the bits of the SSW status word for monitoring device operation.

S5.2 Command Word

Describes the command word for controlling the SSW from various sources.

Configurations (C Configurations)

C8 Communications Configuration

Details configuration for communication accessories and protocols.

C8.1 I/O Data Configuration

Configures the network data exchange area for cyclic communication.

C8.1.1 Data Read Configuration

Configures parameters for reading data over the network.

Operation in PROFINET IO Network

6.1 Cyclic Data Exchange

Explains cyclic data usage for status monitoring and equipment control.

6.1.1 Input Words Configuration

Configures the reading area for cyclic data exchange (inputs sent to master).

6.1.1 Input Words Mapping

Maps parameters to specific input words for cyclic data communication.

6.1.2 Output Words Configuration

Configures the writing area for cyclic data exchange (outputs received from master).

6.1.2 Output Words Mapping

Maps parameters to specific output words for cyclic data communication.

Startup Guide

7.2 Equipment Configuration

Guides on configuring the soft-starter parameters and communication settings.

7.3 Master Configuration

Steps for configuring the PROFINET IO network master using the GSDML file.

Faults and Alarms

Related product manuals