Do you have a question about the WEG SSW-05 Plus Series and is the answer not in the manual?
| Input Voltage | 220-575 V AC |
|---|---|
| Input Frequency | 50/60 Hz |
| Protection Class | IP20 |
| Control Voltage | 24 VDC |
| Output Voltage | 220-575 V AC |
| Protection | Overcurrent, Overvoltage, Undervoltage, Short Circuit |
| Communication Protocols | Modbus RTU |
| Bypass Contactor | Optional |
| Operating Temperature | -10°C to 50°C |
| Humidity | 5 to 95% RH, non-condensing |
| Altitude | Up to 1000 m (3280 ft) without derating |
| Starting Method | Soft start with voltage ramp |
Essential safety precautions before installation and operation.
Introduction to the soft-starter and its function.
Guide to identifying the specific model of the soft-starter.
Specifies input power voltage, current, and operational settings.
Lists fault conditions, error codes, and status LED functions.
Details start duty cycles and digital input configurations.
Covers relay outputs, communication interfaces, environmental conditions, and mounting options.
Lists industry standards the product complies with.
Explains the physical layout and components of the SSW-05 Plus.
Specifies maximum current limits for power supply lines.
Provides physical measurements and weight of the device.
Illustrates a basic start/stop wiring diagram.
Shows wiring for start/stop control using external components.
Wiring for start/stop using push buttons and the operation function relay.
How to set the initial motor voltage for starting.
Adjusting the motor acceleration ramp time.
Adjusting the motor deceleration ramp time.
Setting the motor current for protection and operation.
Explains the N.O. contact operation of the Operation Function relay.
Describes the N.O. contact operation of the Full Voltage Function relay.
Details Overcurrent, Phase Loss, Locked Rotor, and Motor Overload protections.
Covers Phase Sequence, By-pass, Frequency, and Undervoltage protections.
Details electronic overload protection, simulating motor heating with curves.
Methods to reset errors, including button, DI2, and auto-reset.
Lists fault codes (E03, E05, E06, E10) and their reset options.
Explains potential causes for common faults like Phase Loss and Motor Overload.
Covers faults like Locked Rotor, Overcurrent, Phase Sequence, and their causes.
Provides solutions for issues like motor not running or oscillating.
Describes cables for connecting to remote keypads.
Details the RS-232 to RS-485 conversion module.
Describes the remote serial keypad interface.
Details HMI description, LED functions, and key operations.
Explains how to view and program parameters using the HMI.
Covers installation methods and initial startup procedures for the HMI.
Details the function for copying settings between soft-starters.
Lists parameters with ranges, factory, and user settings.
Lists error codes (E03-E75) and their corresponding descriptions.
Explains parameters for access, motor current, software version, and initial voltage.
Describes ramps, motor current, and diagnostic configuration.
Explains diagnostic protections using hexadecimal values.
Provides a comprehensive table for P106 diagnostic configuration.
Details factory reset and parameter copying functions.
Covers HMI selection, digital input, relay output, network address, and serial communication actions.
Defines the parameter for serial communication verification time.
Lists EMC and Low Voltage directives relevant to the product.
Outlines installation requirements for CE compliance.
Official declaration of product conformity to EU standards.
Details the warranty coverage, exclusions, and procedures.