storage
should
'not
exceed
two
years
since
their
delivery.
The
used
batteries
should
be
wiped
clean
fully
chargedb~fore
being
put
aside
separately-
Moreover,
they
should
be
checked
and
recharged
once
a
month.
If
the
used
batteries
are
taken
out
'of
service
for
a
long
period
of
time,
(more
than
6
months)
,they
should
be
stored
witllout
elec-
trolyte.
Therefore,
it
is
necessary
to
discharge
them
with
one
twentieth
of
rated
current
until
the
voltage
of
each
cell
is
lower
than
1. 7
volts,
and
then
drain
off
the
electorlyte
,'and
flush
them
with
distilled
water(once
enery
3
hours)
until
the
water
is
free
of
acidity.
Finally
,dry
them
up
and
store
them
as
the
new
batteries.
F.
Safety
operation:
The
place
where
the
batteries
are
charged
should
he
well
ventilated
and
free
of
fire.
When
the
electrolyte
is
being,
made,
it
is
important
that
pure
sulphuric
acid should,.
be
added
into
dis'tilled
water
,and-
never
'add
the
wate-r
to
the
·acid·.
CZ)Maintenance
of
the
generator
A·.
During
inspecting
and
servicing
·the
generator,
never
test
its
insulation
with
a
megaohm
meter
<ha.nd
winding
meter)
of
with
the
220
volts
A.
C.
power
source.
Only
a
multimeter
with
high
in-
ternal
resistance
can
be
used
such
purpose.
B.
The
generator
should
be
inspected
once
every
750
operating
hours
(It
is
allowed
according
to
the
o'perating
condition,
that
the
generator
may
not
be
serviced
until-
the
fourth
order
maintenance)
.
(3)Miantenance
of
Starting
Motor
A.
Check
regularly
to
see
whether
its
connctions
of
the
fasten-
.•
ing
parts
and
the
conducting
cables
are
firmly
connected
and
clean
the
gathered
dirts
off.
B.
The
stating
motor
should
be
thoroughly
checked
during
the
80