WARNING Fire and shock hazard. Only connect LAN cables contained
within the perimeter of a single building. Conductive LAN cables spanning
multiple buildings may introduce fire or shock hazards unless they are fitted
with fiber optic cables, lightning arresters, or other applicable safety
features.
WARNING Electric shock hazard. This equipment must only be connected
to a supply mains with protective earth.
WARNING Electric shock hazard. Do not open the monitor or attempt
repairs. The monitor has no user-serviceable internal parts. Only perform
routine cleaning and maintenance procedures specifically described in this
manual. Inspection and servicing of internal parts shall only be performed
by qualified service personnel.
WARNING Electric shock hazard. All signal input and output (I/O)
connectors are intended for connection of only devices complying with IEC
60601-1, or other IEC standards (for example, IEC 60950), as applicable to
the monitor. Connecting additional devices to the monitor may increase
chassis or patient leakage currents. To maintain operator and patient
safety, consider the requirements of IEC 60601-1-1. Measure the leakage
currents to confirm that no electric shock hazard exists.
WARNING Explosion or contamination hazard. Improper disposal of
batteries may create an explosion or contamination hazard. Never dispose
of batteries in refuse containers. Always recycle batteries according to local
regulations.
WARNING Use the monitor only as described in this directions for use. Do
not use the monitor on patients as described in the Contraindications.
WARNING Alarm limits are patient- or facility-specific. The clinician must
set or verify alarm limits appropriate for each patient. Each time the
monitor is powered on, you must check that the alarm settings are
appropriate for your patient before you start monitoring.
WARNING Inaccurate measurement risk. The monitor is not intended for
use during patient transport outside of the medical facility. Do not use the
monitor to take measurements on any patient in transit.
WARNING Inaccurate measurement risk. Do not connect more than one
patient to a monitor.
WARNING Inaccurate measurement risk. Dust and particle ingress can
affect the accuracy of blood pressure measurements. Use the monitor in
clean environments to ensure measurement accuracy. If you notice dust or
lint build-up on the monitor's vent openings, have the monitor inspected
and cleaned by a qualified service technician.
WARNING Inaccurate measurement risk. Do not expose to temperatures
higher than 122º F (50º C).
WARNING Inaccurate measurement risk. Do not use the monitor on
patients who are on heart-lung machines.
WARNING Inaccurate measurement risk. Do not use the monitor on
patients who are experiencing convulsions or tremors.
Directions for use About warnings and cautions 9

Table of Contents

Other manuals for Welch Allyn Connex Spot Monitor

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Welch Allyn Connex Spot Monitor and is the answer not in the manual?

Welch Allyn Connex Spot Monitor Specifications

General IconGeneral
Battery LifeUp to 8 hours
Display7 inch color touchscreen
ConnectivityBluetooth, USB
Power SourceAC power, Rechargeable battery
MeasurementsBlood pressure, temperature, SpO2, pulse rate
SpO2 TechnologyMasimo or Nellcor
Optional FeaturesPrinter
Temperature TechnologySureTemp® Plus or Braun Thermoscan® Pro 6000