Device Type | Vital Signs Monitor |
---|---|
Category | Medical Equipment |
Manufacturer | Welch Allyn |
Model | Connex 6000 Series |
Battery Life | Up to 8 hours |
Display | Color touchscreen |
Connectivity | Bluetooth |
Measurement Parameters | Blood pressure, SpO2, temperature, pulse rate |
SpO2 Technology | Pulse oximetry |
Power Source | AC adapter, rechargeable battery |
Explains warning and caution symbols used in the manual.
Lists and explains symbols related to power and battery status.
Lists critical safety warnings and cautions for device use and maintenance.
Provides general guidelines for safe operation and maintenance of the monitor.
Defines the manual's purpose, scope, and intended audience.
Outlines the technical support services offered by Welch Allyn.
Details the steps to navigate and access the device's service screens.
Explains how to restore factory default settings via the General tab.
Describes how to save device settings to a USB flash drive for backup or transfer.
Details how to calibrate the touchscreen using the Self-tests tab.
Outlines the steps to perform the power-on self-test (POST) for the device.
Provides tables of symptoms, possible causes, and suggested actions for troubleshooting.
Addresses troubleshooting steps for issues related to the device not powering up.
Covers troubleshooting steps for display issues like unresponsiveness or dimness.
Lists error codes and initial troubleshooting steps for internal software/hardware issues.
Lists all necessary tools and equipment for disassembly and repair.
Details the procedure for removing the device's battery.
Provides step-by-step instructions to remove the rear housing.
Details how to remove the main board, noting service tool requirement.
Explains how to perform functional tests to ensure device operation and accuracy.
Information about the Welch Allyn Service Tool editions and their use.
Manual procedure to check NIBP accuracy using the service tool.
Steps to perform CO2 calibration or calibration check.
Specifies limits and procedure for checking ground continuity.
Specifies limits for leakage current testing.
Specifies limits for dielectric strength testing.
Lists available options, upgrades, and licenses for different models.
Outlines procedures for installing new device options.
Details Masimo parameter upgrades for specific models.
Part listing and diagram for the rear housing.
Diagram and part listing for the bottom housing.
Diagram and part listing for the top housing.
Guidelines for decontaminating and cleaning the monitor before return for service.
Explains how to identify the monitor's serial number and model.
Lists default settings for general alarm parameters.
Lists default settings for NIBP alarms, intervals, and advanced options.
Lists torque specifications for screws and fasteners used in disassembly.
Describes different connector types and how to connect/disconnect them.