CMP203 User Guide
98
Check or reset Original Network ID and TS ID of each TS (frequency)., Each TS should have
different IDs.
Fill the Original Network ID and TS ID of each TS (frequency) in the field of the base TS
(frequency) and then click Add to create a NIT stream for this TS (frequency).
Click +Descriptor then LCN Descriptor to check all the programs which are contained in this
frequency. Then set programs LCN.
Click +Descriptor and the Cable Descriptor. Then fill in the correct frequency and symbol
rate and choose the correct constellation of the TS (frequency). Then click OK. (This
operation should be set on Modulator module only).
Repeat the operations to add next TS (frequency) until NIT streams of all the
frequencies have been included. Finally click Apply button to let all configuration
take effect. Then searching programs in your STB, you will get all programs in
the order of LCN which you set.