STARTING THE GENERATOR
STARTING THE GENERATOR
1. To use gasoline, turn the fuel valve to the ON position.
To use LPG, make sure all of the LPG connectors and hoses are well connected
and sealed. Close the fuel valve, then open the LPG tank valve.
2. Move the choke lever to the CLOSE/START position.
BEFORE STARTING THE GENERATOR
1. Verify that the generator is outside on a dry, level surface. Allow at least two feet of clearance on all sides of the
generator.
2. To maximize safety, check that the generator is properly grounded (see “GROUND THE GENERATOR”).
3. Check there is sufficient level of oil in the crankcase. Add oil if necessary (see “ADD/CHECK OIL”).
4. Verify the fuel selection dial is turned to the desired fuel. Turn the dial up to 12 o’clock position for gasoline and
down to 6 o’clock position for LPG. Check that there is adequate supply of the selected fuel.
5. Make sure all electrical devices are unplugged from the generator during ignition. Otherwise it will be difficult for
the engine to start.
a. To start the engine with electric starter:
3. Insert the key and turn the engine switch to the
START position for 2-3 seconds. NOTE: If the engine
does not start, release the switch and try again. Keeping
the switch in the START position too long can damage
the starter.
4. When engine starts, release the switch to the ON.
5. Slowly move choke lever to the OPEN/RUN posi-
tion. If engine fires, but does not continue to run, move
choke lever to CLOSE/START position and repeat start-
ing instructions.
b. To start the engine with recoil starter:
3. Turn the engine switch to the ON position.
4. Pull on the recoil starter handle slowly until a slight
resistance is felt, then pull quickly to start the engine.
Return cord gently into the recoil starter. Never allow
the cord to snap back.
If engine fails to start, repeat this step.
5. Once the engine has started, slowly return the choke
lever all the way to the OPEN/RUN position.
6. Allow the engine to run for several minutes before attempting to connect any electrical devices. This allows the
generator to stabilize its speed and temperature. Follow the instructions in the next section for properly connecting
your electrical devices.
NOTE: In case you have had repeated failed attempts to start the engine, please consult the troubleshooting guide
before attempting to start the generator. If problems persist please call (800) 232-1195, M-F 8-5 CST.
20
WARNING: The LPG cylinder valve must be shut OFF when using gaso-
line. The generator’s fuel valve must be shut OFF when using LPG.